    Superstar S6100

    Superstar S6100

    Specifications : Ventilation modes: IPPV; A/C; PCV; SIMV; SIGH; MAUN Ventilator parameter ranges Flow meter O2(0.1-10L/min) N2O(0.1-10L/min) AIR(0.1-10L/min) Rapid oxygen supply 35L/min-75L/min Tidal volume(Vt) 0,....

    Specifications :

    Ventilation modes: IPPV; A/C; PCV; SIMV; SIGH; MAUN
    Ventilator parameter ranges
    Flow meter O2(0.1-10L/min)
    N2O(0.1-10L/min)
    AIR(0.1-10L/min)
    Rapid oxygen supply 35L/min-75L/min
    Tidal volume(Vt) 0, 20 mL ~ 1500 mL
    Frequence(Freq) 1bpm ~ 100 bpm
    I/E 4:1~1:8
    PEEP 0cmH2O ~ 30 cmH2O
    Pressure triggering sensitivity(PTr) -20 cmH2O ~ 0 cmH2O(Based on PEEP)
    Flow trigger sensitivity (FTr) 0.5 L/min ~ 30 L/min
    Pressure control (PC) 5 cmH2O ~ 60 cmH2O
    SIGH 0(off)  1/100 ~ 5/100
    Apnea Ventilation OFF,5 s ~ 60 s
    Pressure Limit 20 cmH2O ~ 100 cmH2O
    Monitored Parameters
    Frequence(Freq) 0 /min ~ 100 /min
    Tidal volume(Vt) 0 mL ~ 2000 mL
    MV 0 L/min ~ 100 L/min
    Oxygen concentration 15 % ~ 100 %
    Graphical display:
    P-T(pressure – time)
    F-T(flow – time)
    P-V loop (pressure – volume loop)
    Size

    Wooden case packing size:L 770*W 890*H 1535mm , GW:151KG ; NW:91.2KG

    Alarm and protection

    The AC power failure alarm Power failure or no connection
    Internal battery backup low voltage alarm <11.3±0.3V
    No tidal volume ≤5Ml within 6s
    High oxygen concentration alarm

    Low oxygen concentration alarm

    19%-100%

    18%-99%

    High Airway  pressure alarm

    Low Airway  pressure alarm

    High Minute Volume alarm

    Low Minute Volume alarm

    Continuous Pressure alarm

    20cmH2O-100cmH2O

    0cmH2O-20cmH2O

    Adult(5L/min-20L/min) Paed(1L/min-15L/min

    0-10L/min)

    (PEEP+1.5kPa) over 16s

    Suffocation warning 5s-60s no spontaneous ventilation
    The maximum limited pressure <12.5 kPa
    Fan error

    Oxygen deficit

    Show on screen

    Show on screen

    Working conditions
    Gas source O2,N2O,AIR
    Pressure 280kPa-600kPa
    Voltage 100-240V
    Power frequency 50/60Hz
    Input power 85VA
    Vaporizer

       

    Anesthesia gas Adjustable scope % (volume percentage)
    Halothane 0 ~ 5
    Enflurane 0 ~ 5
    Isoflurane 0 ~ 5
    Sevoflurane 0 ~ 8
    Leave Your Message

    Related Products

    H2O2 Low Temperature Plasma Sterilizer(Plasma Sterilant Cassette)

    InquiryDetail

    AD-IA(2)NEONATE NCPAP

    InquiryDetail

    CreLed 5700/5500 Hospital Shadowless Operating Lamp

    InquiryDetail

    Endoscope Washer-Disinfector

    InquiryDetail

    Plasma Consumables

    InquiryDetail

    H2O2 Plasma sterilizer

    InquiryDetail

    Surgical Light OT Surgery Ceilings Shadowless 700/700 High End German Style Disc

    InquiryDetail

    Paket Bundling Ruang icu

    InquiryDetail

    Chenwei 201A

    InquiryDetail

    shadowless surgical lamp Build In Camera System

    InquiryDetail
    Leave Your Message